FTTH Drop Pigtail SC/APC G657A1 5.0×2.0mm LSZH Black Steel Messenger Wire Low Loss ≥60dB Return Loss
Product Details:
| Place of Origin: | China |
| Brand Name: | Takfly |
| Model Number: | SM G657A1 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 |
|---|---|
| Price: | US$0.5-US$100 |
| Delivery Time: | 3-12 work days |
| Payment Terms: | T/T |
| Supply Ability: | 30000/Mon |
|
Detail Information |
|||
| Highlight: | FTTH Drop Pigtail SC/APC,G657A1 LSZH Fiber Pigtail,Steel Messenger Wire Pigtail |
||
|---|---|---|---|
Product Description
A field-ready drop pigtail engineered for the last mile: factory-terminated SC/APC connector with anti-vibration design, plug-and-play at the ONU/ONT end, and G657A1 single-mode fiber in a black LSZH 5.0 × 2.0 mm sheath with self-support messenger wire. Fewer field steps, faster subscriber turn-up.
FTTH drop installation rarely fails because the fiber is wrong. It fails because field termination takes too long, because a connector works loose on a vibrating aerial span, or because the installer has to carry a fusion splicer to every subscriber drop. This pigtail addresses those field realities directly.
The connector end is factory-terminated and tested, so the installer plugs it into the ONU/ONT or access terminal without field polishing, epoxy or fusion splicing at that end. The anti-vibration connector design helps maintain mating stability on aerial drops and in enclosures subject to wind or equipment vibration. The far end is prepared for the field connection method specified by the project — fusion splice, mechanical splice or connector — so the assembly fits existing installation practices rather than forcing a new one.
- Plug-and-play at the connector end. No field polishing, no epoxy, no fusion splicer at the ONU/ONT side.
- Anti-vibration connector design. Helps maintain optical contact on aerial spans and in vibrating enclosures.
- Factory-terminated SC/APC. APC end face with ≥60 dB return loss; connector insertion loss ≤0.3 dB.
- G657A1 fiber in a 5.0 × 2.0 mm black LSZH sheath. Suitable for drop cable routing in tight spaces and indoor/outdoor transitions.
- Self-support messenger wire. 1.2 mm steel wire allows aerial self-support deployment without an additional support strand.
- Two 0.45 mm steel strength members. Contribute to tensile and crush resistance during pulling and clamping.
- 1000 mating durability. Insertion loss increase ≤0.2 dB max, supporting repeated connection cycles during installation and maintenance.
- Far end ready for project-specific field connection. Keeps the assembly compatible with existing splice closures and subscriber termination practices.
- Subscriber drop from access terminal or splitter to ONU/ONT
- Aerial self-support drop across short spans
- Rural and suburban FTTH where aerial deployment is practical
- Multi-dwelling and campus drop segments requiring compact cable routing
- Emergency or temporary subscriber activation where speed matters
- Indoor/outdoor transition segments using LSZH sheath
- Projects where field fusion splicing at the subscriber end is already standard practice
- Connector end: remove dust cap, clean end face if required by site practice, and insert into the ONU/ONT or access terminal port until fully seated.
- Far end: prepare and terminate according to the project's standard method (fusion splice, mechanical splice or field-installable connector).
- Aerial deployment: use the 1.2 mm self-support messenger wire for tensioning; avoid exceeding the cable pull limit of 90 N.
- Bend and clamp: respect the cable's minimum bend radius and use clamps that do not crush the 5.0 × 2.0 mm sheath.
- Temperature: installation within -10 °C to +60 °C; operating range -25 °C to +70 °C.
| Parameter | Specification |
|---|---|
| Connector type | SC/APC, single-mode |
| Connector insertion loss | ≤0.3 dB |
| Return loss | ≥60 dB |
| End face | IEC 61300-3-35 |
| Durability (1000 mating) | 0.2 dB max increase |
| Link loss reference @1310 nm | ≤0.3 dB + 0.36 dB/km × L (km) |
| Link loss reference @1550 nm | ≤0.3 dB + 0.25 dB/km × L (km) |
| Cable pull | 90 N |
| Parameter | Specification |
|---|---|
| Fiber type | SM G657A1, 1 core |
| Mode field diameter | 8.6 μm ± 0.4 μm at 1310 nm |
| Cladding diameter | 125.0 μm ± 0.7 μm |
| Coating diameter | 245 μm ± 10 μm |
| Coating-cladding concentricity error | ≤12.5 μm |
| Cut-off wavelength | ≤1260 nm |
| Attenuation coefficient | 1310 nm ≤0.4 dB/km; 1550 nm ≤0.3 dB/km |
| Strength member | Steel wire, 0.45 mm × 2 |
| Self-support messenger wire | Steel wire, 1.2 mm |
| Outer sheath | LSZH, black |
| Cable size | 5.0 × 2.0 mm |
| Parameter | Long Term | Short Term |
|---|---|---|
| Tensile strength | 300 N | 600 N |
| Crush load | 1100 N | 2200 N |
| Parameter | Specification |
|---|---|
| Installation temperature | -10 °C to +60 °C |
| Operating temperature | -25 °C to +70 °C |
| Storage temperature | -40 °C to +75 °C |
| Cladding non-circularity | ≤1.0% |
| Coating diameter (performance table) | 242 ± 7 μm |
Stretch film packaging as standard. Custom packaging and labeling available on request. Length is customized per project; confirm connector type, fiber grade, cable size, sheath color and messenger wire requirement when ordering.
Example order: SC/APC SM G657A1 FTTH drop pigtail, 1 core, 5.0×2.0 mm LSZH black, self-support 1.2 mm steel messenger wire, custom length, stretch film packaging.
Stretch film packaging of the offered products as shown below:
Stretch film packaging overview
Packaging detail




Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews