• 36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection
  • 36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection
  • 36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection
36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection

36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection

Product Details:

Place of Origin: China
Brand Name: DF/OEM/Nuetral
Certification: CE/ROHS/REACH/ISO9001/ISO14001
Model Number: TK-CS-3.0-1M

Payment & Shipping Terms:

Minimum Order Quantity: 100PCS
Price: US$0.01~2.79/PC
Packaging Details: Export Standard Packing
Delivery Time: 5-9 working days depends on QTY
Payment Terms: Western Union,T/T,/Paypal
Supply Ability: 10000PCS/Day
Get Best Price Contact Now

Detail Information

Product Name: ST To LC OM1 OM2 Fiber Optic Duplex Patch Cord Intertion Loss: ≤0.3dB
Return Loss: PC MM ≥ 35 DB Fiber Type: OM1/OM2
Diameter: 3.0mm Connector Type: PC/UPC
Jacket Material: LSZH/PVC/PU Color: Orange Or Customized
Wavelength: 1310nm, 850nm Length: 1M Or Customized
Operation Temperature: -40℃~80℃ Fiber Diameter: 50/125
Grade: Telecom Grade Certificate: CE/ROHS/REACH
Production Capcity: 10000PCS/Day
Highlight:

36CH MT-FA Fiber Array Assembly

,

3x12F MTP V-Groove Fiber Array

,

175/250μm Pitch Low Loss Fiber Array

Product Description

36-channel MT-FA fiber array assembly: three 12-fiber MTP ferrules on one end, a single 36-channel V-groove fiber array facet on the other. FA angle 0°/42.5°, bare fiber angle 8°/42.5°/45°, core pitch 175/250 μm, MT insertion loss ≤0.35 dB, FA insertion loss ≤0.8 dB. MOQ 1 pc.
Product Definition

This is a pre-terminated MT-FA assembly. On one end: three 12-fiber MTP ferrules. On the other: a single 36-channel V-groove fiber array facet. Between them there is no splice, no free-space coupling block and no field termination.

The part exists because optical engines and external ports rarely share the same interface geometry. The engine side wants a tightly pitched array; the port side wants a connector that can be mated, tested and reworked. This assembly carries both in one body, so the module integrator does not have to build an alignment fixture between the two.

Configuration Snapshot
ItemValue
Channel count36
MTP side3 × 12F
FA side1 × 36CH V-groove
Core pitch175 μm / 250 μm
Typical core pitch tolerance< ±0.5 μm
FA angle0° / 42.5°
Bare fiber angle8° / 42.5° / 45°
MT insertion loss≤0.35 dB
FA insertion loss≤0.8 dB
Fiber length20–100 mm, custom
MOQ1 pc
Sample lead time5–7 working days after receiving advance payment
Monthly capacity20K–40K pcs
How to Decide Between 3×12F and a Single 36-Fiber Ferrule

Both configurations exist. The choice is usually driven by how the module will be tested and how the ribbons will be routed.

Choose 3 × 12F when:
  • Your test bench is built around 12-fiber MTP instruments and you do not want a dedicated 36-channel fixture.
  • The optical engine and the external port sit on opposite sides of the package, and three separate ribbons route more cleanly than one wide array.
  • You want to stay on the most widely tooled multi-fiber interface in the supply chain.
Choose a single 36-fiber ferrule when:
  • The module housing allows one wide ribbon and the port side is designed around a 36-fiber connector.
  • You need a single mating event at the external interface rather than three.

This product is the 3×12F option. The FA side is still one 36-channel array, so channel density and pitch at the coupling interface are unchanged.

What the Pitch Tolerance Actually Buys You

The V-groove positions all 36 fibers at either 175 μm or 250 μm pitch. The stated tolerance is < ±0.5 μm typical.

That number is the reason the FA facet can be specified at ≤0.8 dB insertion loss across the array. Pitch error becomes lateral offset at the coupling interface, and on a 36-channel array the error can grow toward the far end. Keeping the typical pitch tolerance inside ±0.5 μm is what holds the far-end channels inside the same loss window as the near-end channels.

Two Loss Numbers, Two Different Interfaces

Do not merge these when you build a link budget.

InterfaceParameterValue
MTP ferruleInsertion loss≤0.35 dB
MTP ferruleReturn lossSM PC ≥50 dB; SM APC ≥60 dB; MM PC ≥20 dB; MM APC ≥40 dB
FA facetInsertion loss≤0.8 dB

The MTP figure is connector-level loss. The FA figure covers V-groove positioning and facet preparation. A module link budget needs both, plus the mating loss at the external port.

Polish selection follows the port: single-mode links with RL ≥60 dB normally call for APC; PC is the usual choice where the port is specified that way. Confirm before ordering.

Available Fiber and Geometry Options
OptionChoices
Fiber modeSM G.652 / G.657; MM OM1 / OM2 / OM3 / OM4 / OM5; PM
Wavelength1310/1550 nm (SM); 850/1300 nm (MM)
MT polishPC / APC
Core pitch175 μm / 250 μm
FA angle0° / 42.5°
Bare fiber angle8° / 42.5° / 45°
Fiber length20–100 mm standard; custom on request
FA lid (L×W×T)2.5 × 2 × 0.2 mm (optional)
V-groove (L×W×T)5 × 2 × 0.5 mm
Durability50 mating cycles
Operating temperature−20 to +80 °C
ComplianceIEC / TIA/EIA; RoHS 2.0
From Drawing to Pilot to Volume

The same production process covers engineering samples and volume orders, which is why the MOQ is set at 1 pc rather than a reel or batch quantity.

StageWhat happens
Drawing reviewSend your MT-to-FA configuration; OEM terms apply
Sample build5–7 working days after receiving advance payment
Pilot runSame line, same process as the sample
Volume20K–40K pcs per month, depending on channel configuration

Custom fiber length runs from 20 mm to 100 mm. Packaging is blister box plus carton as standard; custom packaging on request.

Trade Terms
ItemDetails
MOQ1 pc
Delivery termsEXW, FOB, CFR, CIF, DDU
PaymentT/T, PayPal, Western Union, Alipay
PackagingBlister box + carton; custom on request
Where This Assembly Is Used
  • Active optical modules and high-speed optical engines
  • Optics-to-external-port connections inside fiber equipment
  • Parallel optical transceiver modules
  • High-capacity optical transmission systems
  • Supercomputing and test benches
  • Coherent and PM-fiber module development (PM option)
Ordering Checklist
ItemWhat to specify
Fiber modeSM G.652 / G.657; OM1–OM5; PM
Channel configuration36CH (3×12F) standard; others per drawing
Core pitch175 μm or 250 μm
MT polishPC or APC
FA angle0° or 42.5°
Bare fiber angle8° / 42.5° / 45°
Fiber length20–100 mm or custom
FA lid / V-grooveStandard or per drawing
Packaging and delivery termsPer requirement
Example: 3×12F MTP to 36CH FA assembly, OM4, 250 μm pitch, MT PC, 42.5° bare fiber angle, 50 mm fiber length, blister box.
FAQ
Can the channel configuration be changed?

Yes. 36CH (3×12F) is the baseline; other MT-to-FA layouts are built per drawing under OEM terms.

Why are there two insertion loss figures?

Because there are two interfaces. ≤0.35 dB is the MTP connector; ≤0.8 dB is the FA facet. Both belong in a module link budget.

PC or APC?

Follow the external port. Single-mode with RL ≥60 dB normally means APC; otherwise PC.

How many mating cycles?

50, per the current specification.

What is the MOQ?

1 pc.

How fast are samples?

5–7 working days after receiving advance payment.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

J
John
United Kingdom Nov 6.2025
Good quality and good service, working well, thank you!
O
O*a
United States Sep 11.2025
Very satisfied with this purchase. The patch cords work perfectly in our office network setup. Low loss, solid connectors, and fast delivery. Will order again!
R
R*k
Denmark Feb 20.2014
Durable patch cords, well worth it

Want to Know more details about this product
I am interested in 36CH MT-FA Fiber Array Assembly 3x12F MTP V-Groove 175/250μm Pitch Low Loss for Optical Module Internal Connection could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.