• 12CH PM FAU Fiber Array with Lens 250μm 42.5° FC/PM Male for CPO SiPh
  • 12CH PM FAU Fiber Array with Lens 250μm 42.5° FC/PM Male for CPO SiPh
12CH PM FAU Fiber Array with Lens 250μm 42.5° FC/PM Male for CPO SiPh

12CH PM FAU Fiber Array with Lens 250μm 42.5° FC/PM Male for CPO SiPh

Product Details:

Place of Origin: China
Brand Name: DF/OEM/Nuetral
Certification: CE/ROHS/REACH/ISO9001/ISO14001
Model Number: TK-CS-3.0-1M

Payment & Shipping Terms:

Minimum Order Quantity: 100PCS
Price: US$0.01~2.79/PC
Packaging Details: Export Standard Packing
Delivery Time: 5-9 working days depends on QTY
Payment Terms: Western Union,T/T,/Paypal
Supply Ability: 10000PCS/Day
Get Best Price Contact Now

Detail Information

Product Name: ST To LC OM1 OM2 Fiber Optic Duplex Patch Cord Intertion Loss: ≤0.3dB
Return Loss: PC MM ≥ 35 DB Fiber Type: OM1/OM2
Diameter: 3.0mm Connector Type: PC/UPC
Jacket Material: LSZH/PVC/PU Color: Orange Or Customized
Wavelength: 1310nm, 850nm Length: 1M Or Customized
Operation Temperature: -40℃~80℃ Fiber Diameter: 50/125
Grade: Telecom Grade Certificate: CE/ROHS/REACH
Production Capcity: 10000PCS/Day
Highlight:

12CH PM FAU fiber array

,

250μm 42.5° fiber array lens

,

FC/PM male fiber patchcord

Product Description

12-Channel Lensed PM Fiber Array — FAU-to-FC One-Piece Assembly for CPO & SiPh Edge Coupling

A 12-channel polarization-maintaining fiber array with an integrated lensed facet and a keyed FC/PM connector, built as a single FA-FC body rather than a spliced two-piece assembly. Designed for engineers who need a repeatable polarization reference and channel-to-channel uniformity at the coupling interface — before committing to a full CPO or silicon-photonic packaging run.

Why the FA-FC One-Piece Construction Matters at the Coupling Interface

A fiber array entering a silicon-photonic PIC or a coherent engine is rarely the bottleneck by itself. The bottleneck is the interface between the array facet and the chip, and the connector reference used to verify that interface. In a conventional two-piece build, the FA pigtail is terminated to an FC connector through a secondary process. Each additional termination point introduces an alignment variable that sits between the array facet and the measurement reference. When extinction ratio drifts across channels, the cause is harder to isolate: is it the array, the splice, or the connector key?

This assembly removes that ambiguity. The FA and the FC/PM connector share a single body. The polarization reference at the FC key is mechanically continuous with the fiber array facet. That continuity is what makes the 12-channel extinction ratio behavior traceable to a single alignment event, rather than to a chain of separately aligned interfaces.

For teams working on co-packaged optics, silicon-photonic PIC edge coupling, or coherent optical engine bring-up, this matters less as a "time-saving" claim and more as a measurement-integrity property: the polarization state you verify at the connector is the polarization state presented at the array facet, with no intermediate reference shift.

Polarization Performance: Consistency Across All 12 Channels

PM fiber arrays are judged not only by a single-channel extinction ratio number, but by how uniformly that ratio holds across the array. An array can show an excellent PER on channel 1 and degrade toward channel 12 if the slow-axis alignment drifts during V-groove seating and curing.

This array is built around strict polarization-axis alignment control across all 12 channels. The practical result is a channel-to-channel PER consistency that supports polarization-multiplexed coherent architectures, where a weak channel can limit the usable polarization isolation of the entire link. For reference, industry PM FAU specifications commonly target extinction ratio ≥18 dB and slow/fast-axis angular tolerance ≤3°. This assembly is positioned to meet or exceed that baseline through alignment control at the array level, not through post-assembly selection of the best channels.

The keyed FC/PM connector adds a second layer of repeatability: after re-plugging during lab testing or rework, the polarization reference is re-established by the connector key, not by a free-space rotation stage. That reduces the chance that a measurement shift is mistaken for a device degradation.

Lensed Facet: Why 42.5° and What It Changes

The array facet carries an attaching lens with a 42.5° FA angle. The lens is not a separate optical element placed in front of the array; it is integrated at the facet to reshape the beam as it leaves the fiber. For edge coupling into a silicon-photonic PIC, the mode-field mismatch between the fiber and the chip waveguide is a primary loss mechanism. A lensed facet performs mode-field transformation at the interface, which does two things:

  • Reduces coupling loss by better matching the fiber mode to the PIC mode-field.
  • Relaxes alignment tolerance at the die level, because the beam is shaped before it reaches the chip facet — an effect well documented in lensed FAU and beam-expansion approaches for PIC coupling.

The 42.5° angle is a geometry chosen for the coupling configuration, not a generic polish. It is paired with an 8° MT polish at the connector end and a broadband AR coating from 1260 nm to 1650 nm (R < 0.25%, AOI 13° ± 5°), covering O-band through L-band without requiring a coating change for 1310 nm or 1550 nm operation.

Built for Prototype Validation and Low-Volume Pilot Runs

The current 12-channel, 250 μm pitch configuration sits at the practical entry point for CPO and silicon-photonics packaging development. Commercial CPO FAU roadmaps are moving toward 32/36/42 channels and 127/80 μm pitch, but those high-density arrays carry longer lead times and higher NRE because channel scaling and pitch compression both stress alignment yield. A 12-channel 250 μm array gives an engineering team a representative PM coupling interface without the cycle-time penalty of a high-channel-count custom build.

The product is therefore aimed at:

  • CPO and silicon-photonic PIC edge-coupling prototypes, where the FA facet geometry and polarization reference need to be locked before scaling channel count.
  • Coherent optical engine bring-up, where 12 parallel PM channels are enough to exercise a multi-channel polarization path.
  • Photonic integrated test benches, where a keyed, repeatable PM reference simplifies reconfiguration between measurements.
  • Low-volume pilot runs that bridge the gap between a single lab coupon and a production-intent FAU design.

Standard core pitch options are 127 μm and 250 μm, with UPC, APC, or angled polishing available. Pigtail length is customized; the current build is 10 cm bare fiber, male MT gender, packed in a plastic box, with a 2–7 week lead time depending on configuration.

Technical Specifications
Parameter Unit Value
Channel countCH12
Fiber mode—PM (polarization-maintaining)
Cable type—Bare fiber
Core pitchμm250 ± 0.5 (customizable; 127 μm available)
Fiber MFDμm9 (customizable)
FA polish angledegree42.5° (customizable)
MT polish angledegree8° (customizable)
Insertion lossdBLow insertion loss (per assembly test report)
Return lossdB≥ 55
Operating wavelengthnm1310 / 1550
AR coating (FA/MT)nm1260–1650 nm, R < 0.25%, AOI 13° ± 5°
Connector interface—FC/PM, keyed
MT gender—Male
Lengthcm10 (customized)
Packing—Plastic box
Lead timeweeks2–7
What to Specify Before Ordering

Because this is a coupling-interface component, the parameters that most affect fit are not all captured by a standard pitch-and-angle table. The following should be confirmed against the actual PIC or optical engine layout:

Item Why it matters
PIC mode-field diameter / coupler geometryDetermines whether the integrated lens at 42.5° produces the intended spot size at the facet.
Required PER and channel uniformityDefines the acceptance window for polarization-axis alignment across all 12 channels.
FA facet angle and AR coating band42.5° and 1260–1650 nm are the current build; confirm against the coupling angle and wavelength plan.
Pigtail length and fiber jacket10 cm bare fiber is the current configuration; longer lengths and jacketing affect packaging and bend management.
Connector key orientation vs. PIC polarization axisThe FC key is the polarization reference; its angular relationship to the PIC axis must be fixed at design stage.
Test report contentConfirm whether per-channel IL and PER data are required, and at which wavelengths.
Example configuration: 12CH PM FAU with attaching lens, 250 μm pitch, 42.5° FA angle, 8° MT, FC/PM male, 10 cm bare fiber, AR 1260–1650 nm, plastic box packaging.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

J
John
United Kingdom Nov 6.2025
Good quality and good service, working well, thank you!
O
O*a
United States Sep 11.2025
Very satisfied with this purchase. The patch cords work perfectly in our office network setup. Low loss, solid connectors, and fast delivery. Will order again!
R
R*k
Denmark Feb 20.2014
Durable patch cords, well worth it

Want to Know more details about this product
I am interested in 12CH PM FAU Fiber Array with Lens 250μm 42.5° FC/PM Male for CPO SiPh could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.