MPO MTP 12F to CS Duplex Breakout Patch Cord, 8/12/24 Fiber, Low Loss
Product Details:
| Place of Origin: | Shenzhen, China |
| Brand Name: | Takfly/OEM |
| Certification: | CE, ISO, RoHS, GS |
| Model Number: | MPO/MTP Patch cord |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1pcs |
|---|---|
| Price: | US $0.12-US $19.88/ Pcs |
| Packaging Details: | PP Bag Then in Carton |
| Delivery Time: | 3-7working day |
| Payment Terms: | L/C,T/T,Western Union,Paypal |
| Supply Ability: | 300000pcs/Month |
|
Detail Information |
|||
| Core: | Multicore | Connector A: | SC |
|---|---|---|---|
| Connector B: | MPO /MTP | Fiber Mode: | 50/125um |
| Cable Diameter: | 0.9/2.0/3.0 | Polish Type: | PC/APC |
| Return Loss: | MM/PC:20dB/SM/APC:60dB | Insertion Loss: | 0.35dB Max (0.15dB Typ.) |
| Outer Sheath Material: | PVC/LSZH | Bending Radius Static/Dynamic: | 10d/20d |
| HS Code: | 854470000 | Gender: | Male/Female |
| Highlight: | MPO MTP 12F breakout patch cord,CS duplex breakout patch cord,low loss 8/12/24 fiber |
||
Product Description
8 / 12 / 24 Fiber | OS2, OM1–OM5 | Low Loss | LSZH & PVC | Custom Length
One MPO trunk, up to 12 CS duplex ports. Factory fan-out from a backbone MPO trunk to CS duplex connectors—no cassette, no splice, no field termination.
| Fiber Count | CS Duplex Ports |
|---|---|
| 8F | 4 |
| 12F | 6 |
| 24F | 12 |
The assembly breaks the MPO trunk out to CS duplex connectors through a factory fan-out, providing a direct path from the backbone trunk to duplex 100G / 200G / 400G transceiver ports or CS patch panels.
- One MPO trunk, multiple CS duplex ports. 8F, 12F and 24F configurations map to 4, 6 and 12 CS duplex ports respectively.
- Low loss for real power budgets. MPO low-loss grade at 0.20 dB typical / 0.35 dB max; CS at ≤0.3 dB max. Suitable for duplex 100G / 200G / 400G links and CS patch-panel runs. MPO-based parallel trunks can terminate at the MPO end—confirm lane mapping for SR4 / DR4 / SR8.
- CS: higher density than LC duplex. Compact dual-fiber push-pull interface, roughly half the footprint of an LC duplex pair—significantly more ports per 1U panel. CS connectors require CS adapters/panels; they are not LC-compatible.
- Polarity A / B / C. Straight, crossed or TIA-568 Type C pinouts to match your cassette and trunk scheme.
A single MPO-8 / MPO-12 / MPO-24 trunk connector on one end is broken out by a factory fan-out into CS duplex connectors on the other. Typical use: rack-to-rack backbone cabling where an MPO trunk leaves the MDA and terminates directly on duplex 100G / 200G / 400G optics, or on a CS patch panel—with no cassette, no splice and no field termination in between.
Available in OS2 single-mode (G.652.D, G.657.A2; optional G.655 NZDSF to be confirmed) and multimode OM1 to OM5, with UPC or APC end faces.
- Data center backbone: MDA / HDA / EDA trunk-to-duplex optics
- Duplex 100G / 200G / 400G optics and CS patch panels
- MPO-based parallel trunks at the MPO end (lane mapping to be confirmed)
- QSFP, QSFP28 and QSFP-DD duplex transceiver interfaces
- Pre-terminated structured cabling systems
- MPO to CS patch panel, adapter panel and cassette feeds
- Hyperscale, enterprise and colocation builds
- Active device / transceiver test and lab setups
- CATV, video and multimedia networks
- Telecom central office and OSP termination
- Industrial and medical imaging
| Parameter | Specification |
|---|---|
| Fiber count per assembly | 8 / 12 / 24 |
| CS duplex ports | 4 / 6 / 12 |
| MPO fiber count | 8 / 12 / 24 |
| Fiber type | SM: OS2 G.652.D / G.657.A2; optional G.655 (NZDSF)—classification to be confirmed; MM: OM1, OM2, OM3, OM4, OM5 |
| Polarity | Type A / Type B / Type C |
| Jacket / outer diameter | LSZH or PVC; branch 2.0 mm or 3.0 mm; trunk mini-round max 4.5 mm / ribbon max 3.0 × 5.0 mm |
| Operating temperature | -20 °C to +70 °C |
| Storage temperature | -40 °C to +80 °C |
| Bending radius (static / dynamic) | 10D / 20D (D = cable outer diameter) |
| Length | Customized; L = total assembly length, MPO connector to CS connector tip; L1 = fan-out leg length from breakout boot to CS tip |
| Standards | IEC 61754-7; EIA/TIA-604-5; TIA-568.3-D |
| Parameter | CS Connector | MPO / MTP® Connector |
|---|---|---|
| End face type | UPC and APC | PC and APC |
| Insertion loss (dB) | ≤ 0.3 max | Standard: 0.35 typ / 0.70 max; Low loss: 0.20 typ / 0.35 max |
| Return loss (min) | UPC SM: 40 dB; APC SM: 60 dB; PC MM: 25 dB | SM APC: 60 dB; MM PC: 20 dB |
| Test wavelength (nm) | SM: 1310 / 1550; MM: 850 / 1300 | SM: 1310 / 1550; MM: 850 / 1300 |
| Repeatability | ≤ 0.1 dB | Per IEC 61754-7 / TIA-604-5 |
| Durability | ≤ 0.2 dB | Per IEC 61754-7 / TIA-604-5 |
| Interchangeability | ≤ 0.2 dB | Per IEC 61754-7 / TIA-604-5 |
| Option | Available Configuration |
|---|---|
| Connector A | MPO / MTP®—8F, 12F or 24F—male (pinned) or female (unpinned) |
| Connector B | CS duplex—UPC (blue) or APC (green) |
| Fiber | SM: OS2 G.652.D / G.657.A2; optional G.655 (NZDSF)—classification to be confirmed; MM: OM1, OM2, OM3, OM4, OM5 |
| Polarity | Type A (straight) / Type B (crossed) / Type C |
| Jacket / OD | LSZH or PVC—2.0 mm or 3.0 mm—riser / plenum on request |
| Length | Customized—total length L, fan-out leg L1 |
| Options | LC or SC far end—ribbon cable—armored or plenum jacket—split leg lengths |
Ordering example: MPO-12 male to 6× CS UPC, OM4, Type B, LSZH 3.0 mm, L=10 m, L1=0.5 m.
- IEC 61754-7—MPO / MTP® ferrule and adapter interface
- EIA/TIA-604-5—FOCIS-5 MPO connector intermateability
- TIA-568.3-D—Polarity A / B / C methods supported
- Precision molded MT ferrule—ferrule flatness and fiber position held to tight micron-level tolerance
- High-precision guide pins—precise alignment of the 8 / 12 / 24 fiber array
- Compact breakout—rugged fan-out boot, 2.0 / 3.0 mm microcable, 10D / 20D bend radius
Insertion loss and return loss are measured per assembly. The assembly is 100% tested, and a serialized test report can be supplied with the shipment on request. Labels carry part number, fiber count, polarity and length.
Custom builds are available on request, including mixed fiber counts, mixed CS / LC ends, ribbon or mini-round cable, plenum-rated jacket and split leg lengths.
Compliance: IEC 61754-7, EIA/TIA-604-5 and TIA-568.3-D. Additional certifications and order-specific documentation are available per order agreement.
MOQ and lead time are project-dependent; confirm with sales for the exact 8F / 12F / 24F configuration, polarity, connector gender and test-report requirement.