Takfly MPO/MTP Patch Cord 8/12/24 Cores up to 576 Cores Low Loss 500 Mating Cycles IEC & TIA Compliant
Product Details:
| Place of Origin: | Shenzhen, China |
| Brand Name: | Takfly/OEM |
| Certification: | CE, ISO, RoHS, GS |
| Model Number: | MPO/MTP Patch cord |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1pcs |
|---|---|
| Price: | US $9.88-US $19.88/ Pcs |
| Packaging Details: | PP Bag Then in Carton |
| Delivery Time: | 3-7working day |
| Payment Terms: | L/C,T/T,Western Union,Paypal |
| Supply Ability: | 50000pcs/Month |
|
Detail Information |
|||
| Core: | Multicore | Connector A: | SC |
|---|---|---|---|
| Connector B: | MPO /MTP | Fiber Mode: | 50/125um |
| Cable Diameter: | 0.9/2.0/3.0 | Polish Type: | PC/APC |
| Return Loss: | MM/PC:20dB/SM/APC:60dB | Insertion Loss: | 0.35dB Max (0.15dB Typ.) |
| Outer Sheath Material: | PVC/LSZH | Bending Radius Static/Dynamic: | 10d/20d |
| HS Code: | 854470000 | Gender: | Male/Female |
| Highlight: | MPO MTP patch cord low loss,MPO MTP cable 500 mating cycles,MPO MTP fiber optic IEC compliant |
||
Product Description
The MPO/MTP multi-fiber connector series is engineered for high-density optical interconnections in data centers, telecom central offices, CATV headends, and industrial environments. A precision-molded MT ferrule combined with high-accuracy guide pins ensures exact alignment of up to 24 fibers in a single interface, with custom configurations available up to 576 fibers for ultra-scale deployments.
Takfly Communications brings 25+ years of ODM/OEM manufacturing expertise to this series. We operate 30,000㎡ of production space across a 6,000㎡ R&D headquarters in Shenzhen and a 24,000㎡ high-volume plant in Zhongshan, running 19 dedicated MPO production lines with a monthly output exceeding 200,000 pieces. Two performance grades—standard and low-loss—are available to match diverse link budget requirements. All products meet IEC 61754-7 and EIA/TIA-604-5, with 100% factory testing before delivery.
- Precision molded MT ferrule for consistent core geometry
- High-precision guide pins for reliable alignment after repeated mating
- Supports 4, 8, 12, 24 fibers in a compact form factor; custom solutions up to 576 fibers
- Standard loss: ≤0.35 dB typical / ≤0.70 dB max
- Low loss: ≤0.20 dB typical / ≤0.35 dB max
- Compatible with single-mode (G.652, G.655, G.657) and multi-mode (OM1~OM5) fibers
- Multiple cable types: mini round (≤4.5 mm OD) or ribbon (≤3.0×5.0 mm)
- Jacket options: PVC or LSZH (low smoke, halogen-free, CPR Bca/Cca/Dca certified)
- Polarity management: Type A, B, C with color coding and labeling
- Male (with pins) and female (without pins) versions available
| Parameter | Specification |
|---|---|
| Connector Type | MPO / MTP (Male with pins / Female without pins) |
| End Face | PC (MM) / APC (SM) |
| Fiber Type | SM: G.652, G.655, G.657; MM: OM1, OM2, OM3, OM4, OM5 |
| Core Count | 4, 8, 12, 24 (custom up to 576 fibers) |
| Cable Type | Mini Round (≤4.5 mm OD) / Flat Ribbon (≤3.0×5.0 mm) |
| Jacket Material | PVC / LSZH (CPR Bca/Cca/Dca certified) |
| Length | 0.5 m ~ 200 m (customized) |
| Test Wavelength | SM: 1310/1550 nm; MM: 850/1300 nm |
| Insertion Loss (Standard Grade) | Typical ≤0.35 dB / Max ≤0.70 dB |
| Insertion Loss (Low-Loss Grade) | Typical ≤0.20 dB / Max ≤0.35 dB |
| Return Loss (SM APC) | ≥60 dB |
| Return Loss (MM PC) | ≥20 dB |
| Repeatability | ≤0.1 dB |
| Durability | ≤0.2 dB |
| Interchangeability | ≤0.2 dB |
| Bending Radius (Static / Dynamic) | 10D / 20D |
All MPO/MTP patch cords undergo rigorous environmental screening to ensure long-term stability in demanding deployments:
- Mating Cycles: ≥500 (insertion loss variation ≤0.2 dB)
- Tensile Strength: ≥50 N (for 2.0 mm cable, connector to cable)
- Damp Heat Cycling: -10℃ to +65℃, 93% RH, 5 cycles -> ΔIL ≤0.3 dB (IEC 61300-2-19)
- High-Temperature Aging: 85℃ for 168 hours -> ΔIL ≤0.3 dB
- Low-Temperature Storage: -40℃ for 24 hours -> ΔIL ≤0.2 dB
- Vibration & Shock: Meets GR-1435-CORE requirements for industrial use
- Thermal Cycling: Compliant with IEC 61300-2-22
- Operating Temperature: -20℃ ~ +70℃
- Storage Temperature: -40℃ ~ +80℃
| Application | Example | Benefit |
|---|---|---|
| Data Center - 40G/100G/400G Links | 12-fiber low-loss MPO patch cord connecting QSFP-40G-SR4 to the patching area | Replaces 4 duplex LC pairs, saves 75% of cable tray space |
| Data Center - 800G/AI Cluster Interconnect | 24-fiber or 576-fiber MPO trunk between spine switches and GPU racks | Supports next-gen 800G optics and AI training clusters with ultra-low loss budget |
| Telecom Central Office - Backbone Upgrade | 24-fiber MPO ribbon cable connecting ODF sub-racks with MPO-LC breakout modules | Rapid deployment, ready for 400G coherent optics |
| 5G Front-haul & Mid-haul | 8-fiber MPO jumper connecting BBU/DU to AAU/RU via CPRI/eCPRI | Reduces installation time by 60% vs. individual fiber splicing |
| Industrial - Ruggedized Interconnect | Vibration-resistant MPO jumper, operating temp -40℃ to +85℃, passed shock & vibration testing | Salt spray and mold resistance for harsh environments |
| CATV Headend - Multi-Channel Video Distribution | 1×12 MPO splitter feeding 12 optical receivers | High density, reduces cable clutter |
| Enterprise LAN/SAN - Campus Backbone | 24-fiber MPO trunk between main distribution frame and building closets | Future-proof scalability for 10G/25G/40G server connectivity |
| Comparison Item | Standard MPO (Market Average) | Takfly MPO/MTP Series |
|---|---|---|
| Manufacturing Scale | Limited capacity | 30,000㎡ total (6,000㎡ Shenzhen HQ + 24,000㎡ Zhongshan plant) |
| MPO Production Lines | 3-5 lines typical | 19 dedicated MPO lines |
| Monthly Output | 20,000-50,000 pcs | 200,000+ pcs/month |
| Max Fiber Count | 24-48 cores | Up to 576 cores |
| Typical Insertion Loss | 0.50 dB | 0.35 dB (Standard) / 0.20 dB (Low-Loss) |
| Mating Cycles | 200 | ≥ 500 |
| Max Operating Temperature | 70℃ | 85℃ (short-term), 70℃ (long-term) |
| Polarity Management | Optional / Manual | Full Type A/B/C with color coding |
| Environmental Test Data | Not specified | Damp heat, thermal cycle, vibration reports available |
| Custom Lengths | Limited | Any length from 0.5 m to 200 m |
| Cable Diameter | Standard bulk | Mini round ≤4.5 mm / Ribbon ≤3.0×5.0 mm |
Takfly offers fully customizable MPO/MTP patch cords to match your exact project requirements. Available options include:
- Core Count: 4 / 8 / 12 / 24 fibers (custom up to 576 fibers)
- Loss Grade: Standard or Low-Loss
- Cable Type: Mini Round or Flat Ribbon
- Outer Sheath: PVC or LSZH (CPR Bca/Cca/Dca certified)
- End Face: PC (multi-mode) or APC (single-mode)
- Polarity: Type A (straight), Type B (reversed), or Type C (pairwise) with color-coded boots
- Connector Gender: Male (with guide pins) or Female (without pins)
- Length: Any length from 0.5 m to 200 m
- Breakout Fanout: MPO to LC/SC/FC breakout cables available upon request
- 100% IL & RL tested -- Each patch cord comes with an individual test report
- 3D interferometer inspection -- Radius of curvature, fiber height, and apex offset per IEC standards
- Production standards -- IEC, Europe standard, IPC/WHMA-A-620 workmanship criteria
- Certifications -- CE, ISO 9001, ISO 14001, RoHS, REACH, FCC, CPR EN50575, ANATEL
- Traceability -- Unique serial numbers and batch test records for every shipment
This MPO/MTP multi-fiber patch cord series offers standard and low-loss grades, enhanced mechanical durability (≥500 mating cycles), proven environmental stability (damp heat, high-temp aging, low-temp storage), and full polarity management (Type A/B/C). Manufactured across 30,000㎡ of facilities with 19 dedicated MPO lines and monthly capacity exceeding 200,000 pieces, Takfly delivers scalable, high-reliability fiber interconnections for data centers, telecom, 5G, AI clusters, CATV, and industrial applications. All specifications are factory-tested, and custom configurations up to 576 fibers are available.
- 100% insertion loss and return loss testing on every patch cord
- 3D interferometry inspection for connector end-face geometry
- Environmental screening per IEC 61300-2 series (damp heat, thermal cycling, vibration)
- Unique serial numbers and batch test reports for full traceability
- Standard products: 2-3 working days for up to 5,000 pcs (maintained in stock)
- Custom configurations: 3-9 working days depending on cable type, polarity, and length
- Urgent orders: We maintain buffer stock of popular configurations and can expedite production for time-critical deployments
- Inquiry -- Email product name, specification, and quantity. Include your delivery address for freight-inclusive pricing.
- Quotation -- Receive detailed quotation with lead time and terms within 12 -24 hours.
- Confirmation -- Approve the quotation; we issue a Proforma Invoice (PI).
- Payment -- T/T, Western Union, or PayPal. For large orders: 50% deposit + 50% balance before shipment.
- Production -- Manufacturing begins with weekly progress updates.
- Delivery -- Confirm consignee and shipping method; tracking numbers provided within 24 hours of dispatch.
- After-Sales -- Dedicated support follows up on installation and performance.
- Pre-sales fiber infrastructure design consultation
- Polarity management training (Type A/B/C)
- Installation best practices for MPO/MTP connectors
- Post-deployment troubleshooting and OTDR trace analysis
- On-site support for large data center projects (by arrangement)





Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews