1RU 19" Rack 40CH Thermal AWG DWDM Mux Demux For Networks Building
Product Details:
Place of Origin: | China |
Brand Name: | Takfly/OEM/Neutral |
Certification: | CE,ROHS,REACH,ISO9001,ISO14001 |
Model Number: | TK-DWDM-40CH |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 piece |
---|---|
Price: | US$0.01 ~ US$1200/PC |
Packaging Details: | spone + box + carton |
Delivery Time: | 3-9working days |
Payment Terms: | Western Union, T/T, MoneyGram/Paypal |
Supply Ability: | T/T, Western Union, MoneyGram, Paypal, L/C |
Detail Information |
|||
Channel: | 40CH | Wavelength: | C20~C60 |
---|---|---|---|
Dimension: | 1U 19Inch | Connector: | LC |
Operating Temperature: | -5~65℃ | Storage Temperature: | -40~85℃ |
Fiber Type: | SMF28e With 900um Loose Tube Fiber | Operating Humidity: | 5~95%RH |
Storage Humidity: | 5~95%RH | Certificate: | CE, ROHS, REACH, ISO9001, ISO14001 |
Output Channels: | 40 | Channel Spacing: | 100GHz |
Operating Band: | C Band | Insertion Loss: | 5.5dB, Max : 6.0dB |
High Light: | 40CH WDM Mux Demux,40CH Wavelength Division Multiplexer,FTTX WDM Mux Demux |
Product Description
1RU 19" Rack 40CH Thermal AWG DWDM Mux Demux For Networks Building
40CH DWDM with LC/UPC optical adapter interface. Standalone 1RU 19" rack packing Mux + Demux inside. ITU channel 21-60.
The 1x40 DWDM Mux Demux is a 40-channel standalone product in a compact 1RU frame that is capable of dense wavelength division multiplexing (DWDM) and demultiplexing. With its dense signal-to-fiber ratio, the 40CH Filter DWDM mux demux is ideal for long-haul transport of fiber optic signals. Use it to multiplex and transport a large number of signals of various formats — all over a dual fiber.
This component is designed for use within the C -band release of DWDM system. To decrease the power dissipation of the devices in different environmental conditions, the AWG package is special designed with selection of reliable thermal plastic with low thermal conduction, and the AWG operating temperature is controlled by using foil resist heater or Peltier TEC with thermistor temperature sensor.
40CH DWDM Mux Demux Features:
-
Multi-channel number Low insertion
-
loss and PDL High channel isolation
-
MUX and DEMUX functionality
-
Qualified under Telcordia 1209/1221 and RoHS compliant
40CH DWDM Mux Demux Applications:
-
DWDM transmission Metro Area
-
Networks Long Haul Networks Building
-
Blocks for ROADM
40CH DWDM Mux Demux Optical Specifications
Parameter | Unit | Value | Other | ||||
Min. | Typ. | Max. | |||||
Output Number of Channels | 40 | ||||||
Channel Spacing | GHz | 100 | |||||
Operating Band | C Band | ||||||
Center Wavelength Accuracy | pm | 50 | 50 | ||||
1dB Bandwidth | pm | 40 | |||||
3dB Bandwidth | pm | 60 | |||||
Insertion Loss | dB | 5.5 | 6.0 | ||||
Ripple | dB | 0.5 | |||||
Insertion Loss Uniformity | dB | 1.5 | |||||
Adjacent Channel Crosstalk | dB | 23 | |||||
Non-Adjacent Channel Crosstalk | dB | 30 | |||||
Total Crosstalk | dB | 21 | |||||
Polarization Dependent Loss | dB | 0.5 | |||||
Polarization Mode Dispersion | ps | 0.5 | |||||
Chromatic Dispersion | ps/nm | -20 | +20 | ||||
Return Loss | dB | 40 |
Remark:
1. Output Number of Channels 8, 16,32, 48 channels available;
2. IL Represents the worst case over a +/- 12.5GHz window around the ITU wavelength ;
3. PDL was measured on average polarization over a +/- 12.5GHz window around the ITU wavelength.
Wavelength Plan
No | C Even | C Even + | C Odd | C Odd + | ||||
f(THz) | λ(nm) | f(THz) | λ(nm) | f(THz) | λ(nm) | f(THz) | λ(nm) | |
1 | 196.000 | 1529.553 | 196.025 | 1529.358 | 196.050 | 1529.163 | 196.075 | 1528.968 |
2 | 195.900 | 1530.334 | 195.925 | 1530.139 | 195.950 | 1529.944 | 195.975 | 1529.748 |
3 | 195.800 | 1531.116 | 195.825 | 1530.920 | 195.850 | 1530.725 | 195.875 | 1530.529 |
4 | 195.700 | 1531.898 | 195.725 | 1531.702 | 195.750 | 1531.507 | 195.775 | 1531.311 |
5 | 195.600 | 1532.681 | 195.625 | 1532.485 | 195.650 | 1532.290 | 195.675 | 1532.094 |
6 | 195.500 | 1533.465 | 195.525 | 1533.269 | 195.550 | 1533.073 | 195.575 | 1532.877 |
7 | 195.400 | 1534.250 | 195.425 | 1534.054 | 195.450 | 1533.858 | 195.475 | 1533.661 |
8 | 195.300 | 1535.063 | 195.325 | 1534.839 | 195.350 | 1534.643 | 195.375 | 1534.446 |
9 | 195.200 | 1535.822 | 195.225 | 1535.625 | 195.250 | 1535.429 | 195.275 | 1535.232 |
10 | 195.100 | 1536.609 | 195.125 | 1536.412 | 195.150 | 1536.216 | 195.175 | 1536.019 |
11 | 195.000 | 1537.397 | 195.025 | 1537.200 | 195.050 | 1537.003 | 195.075 | 1536.806 |
12 | 194.900 | 1538.186 | 194.925 | 1537.989 | 194.950 | 1537.792 | 194.975 | 1537.594 |
13 | 194.800 | 1538.976 | 194.825 | 1538.778 | 194.850 | 1538.581 | 194.875 | 1538.383 |
14 | 194.700 | 1539.766 | 194.725 | 1539.568 | 194.750 | 1539.371 | 194.775 | 1539.173 |
15 | 194.600 | 1540.557 | 194.625 | 1540.359 | 194.650 | 1540.162 | 194.675 | 1539.964 |
16 | 194.500 | 1541.349 | 194.525 | 1541.151 | 194.550 | 1540.953 | 194.575 | 1540.755 |
17 | 194.400 | 1542.142 | 194.425 | 1541.944 | 194.450 | 1541.746 | 194.475 | 1541.548 |
18 | 194.300 | 1542.936 | 194.325 | 1542.737 | 194.350 | 1542.539 | 194.375 | 1542.341 |
19 | 194.200 | 1543.730 | 194.225 | 1543.532 | 194.250 | 1543.333 | 194.275 | 1543.135 |
20 | 194.100 | 1544.526 | 194.125 | 1544.327 | 194.150 | 1544.128 | 194.175 | 1543.929 |
21 | 194.000 | 1545.322 | 194.025 | 1545.123 | 194.050 | 1544.924 | 194.075 | 1544.725 |
22 | 193.900 | 1546.119 | 193.925 | 1545.920 | 193.950 | 1545.720 | 193.975 | 1545.521 |
23 | 193.800 | 1546.917 | 193.825 | 1546.717 | 193.850 | 1546.518 | 193.875 | 1546.318 |
24 | 193.700 | 1547.715 | 193.725 | 1547.516 | 193.750 | 1547.316 | 193.775 | 1547.116 |
25 | 193.600 | 1548.515 | 193.625 | 1548.315 | 193.650 | 1548.115 | 193.675 | 1547.915 |
26 | 193.500 | 1549.315 | 193.525 | 1549.115 | 193.550 | 1548.915 | 193.575 | 1548.715 |
27 | 193.400 | 1550.116 | 193.425 | 1549.916 | 193.450 | 1549.715 | 193.475 | 1549.515 |
28 | 193.300 | 1550.918 | 193.325 | 1550.717 | 193.350 | 1550.517 | 193.375 | 1550.317 |
29 | 193.200 | 1551.721 | 193.225 | 1551.520 | 193.250 | 1551.319 | 193.275 | 1551.119 |
30 | 193.100 | 1552.524 | 193.125 | 1552.323 | 193.150 | 1552.122 | 193.175 | 1551.922 |
31 | 193.000 | 1553.329 | 193.025 | 1553.128 | 193.050 | 1552.926 | 193.075 | 1552.725 |
32 | 192.900 | 1557.134 | 192.925 | 1553.933 | 192.950 | 1553.731 | 192.975 | 1553.530 |
33 | 192.800 | 1554.940 | 192.825 | 1554.739 | 192.850 | 1554.537 | 192.875 | 1554.335 |
34 | 192.700 | 1555.747 | 192.725 | 1555.545 | 192.750 | 1555.343 | 192.775 | 1555.142 |
35 | 192.600 | 1556.555 | 192.625 | 1556.353 | 192.650 | 1556.151 | 192.675 | 1555.949 |
36 | 192.500 | 1557.363 | 192.525 | 1557.161 | 192.550 | 1556.959 | 192.575 | 1556.757 |
37 | 192.400 | 1558.173 | 192.425 | 1557.970 | 192.450 | 1557.768 | 192.475 | 1557.566 |
38 | 192.300 | 1558.983 | 192.325 | 1558.780 | 192.350 | 1558.578 | 192.375 | 1558.375 |
39 | 192.200 | 1559.794 | 192.225 | 1559.591 | 192.250 | 1559.389 | 192.275 | 1559.186 |
40 | 192.100 | 1560.606 | 192.125 | 1560.403 | 192.150 | 1560.200 | 192.175 | 1559.997 |
Absolute Maximum Rating
Parameter | Unit | Value | ||
Min. | Typ. | Max. | ||
Maximum Continuous Optical Power | mW | 300 | ||
Operating Temperature | ℃ | -5~65 | ||
Storage Temperature | ℃ | -40~85 | ||
Operating Humidity | %RH | 5~95 | ||
Storage Humidity | %RH | 5~95 |
Remark: Unless otherwise specified
Mechanical Schematic and Dimensions
Fiber Connector Specifications
Parameter | Unit | Specification |
Fiber Type | SMF28e with 900um Loose Tube Fiber | |
Fiber Format | 2 x 8 + 2 x 12 -Fiber ribbons | |
Input Common Fiber Length | mm | 1000+/-50 |
Ribbon Fiber | mm | 1000+/-50 |
Fanout Fiber | mm | 500+/-50 |
Connector Type | LC/UPC |
Remark:
Fiber length and Connector Type is available to change by customer’s request.
Ordering Part Code Sequence
AAWG-F40-100-C21-05-1050-LU
AAWG F40 100 | C21 | 05 | 1050 | LU | |||
Passband Profile | Channel Number | Channel Spacing | First Channel | Common Length |
Ribbon /Fan Fiber Length |
Connector Type | |
F=Flat-Top | 16:16 Ch | 100=100GHz | C21=C21 | 05:0.5m | 05:0.5m | FU=FC/UPC | |
G=Gaussian | 32:32 Ch | 50=50 GHz | 10:1.0m | 10:1.0m | FA=FC/APC | ||
40:40 Ch | SU=SC/UPC | ||||||
48:48 Ch | SA=SC/APC | ||||||
ST=ST/UPC | |||||||
LU=LC/UPC | |||||||
LA=LC/APC |
Why choose TAKFLY--- Advantages as follows:
Professional manufacturer:
- More than 20 years manufacturing experience in Fiber optic products-one stop purcharsing.
- More than 450 assembly workers with 3 years experienced;
- More than 26 R&D Engineers;
- 16 Sets Germany imported Injection Machine and More than 10 Cable Production Lines;
- More than 30 sets of Testing Machines: OTDR,3D,VFL,IL&RL test instrument; tension strenth tester, Crush Resistance tester, Power meter tester, light checker, ect.
- OEM Brand is acceptable.
- Exhibition: OFC, ECOC, CommunicAsia, NETCOM, AFRICACOM, SVIAZ ICT, CommunicIndonesia ,Global Soure Electronic Exhibition,etc.
- After-sales Services: Available for 24 hours.
Quality Control:
- Spot check the raw material incoming inspection before production;
- Fully check after every individual process finished;
- Fully check production half done;
- Fully check the finished products before packing;
- Spot check before shipping;
Delivery:
- Samples: 1-3 working days.
- Mass Production Order: 3-7 working days.
- Packaging: Plastic Bag, Carton and Pallet are available according to your request.
Price: If your QTY is big, the price could be negotiated.
I have been working in this field more than 6 years, I believe, I could give you very good service and professional answers!